・ The maximum size of numeric characters is 3116. And the maximum

alphanumeric capability is 2335. Excess field data will cause no symbol to be

printed.

^BY

Bar Code Field Default

Description:

The ^BY command is used to change the default values for the Narrow Element Module(Narrow Bar

or Space)Width, the Wide Bar to Narrow Bar Width Ratio and the Bar Height. It can be used as often

as necessary within a label format.

Format: ^BYw,r,h

Parameters:

w = module(narrow bar) width (in dots)

Accepted Values: 1 to 10

Initial Value at Power-up:2

r = wide bar to narrow bar width ratio

Accepted Values:1.0 to 24.0 (not to exceed w*r =24)

h = height of bars (in dots)

Accepted Values: 1 to 7999(200dpi) / 1 to 11998(300dpi)

Initial Value at Power-up: 10

Module width and height (w and h)may be changed at anytime with the ^BY command regardless of

the symbology selected.

Comments:

Once a ^BY command is entered into a label format, it stays in effect until another ^BY command is

encountered.