Parameters:

a = units

Accepted Values:

D = dots

I = inches

M = millimeters

Default Value: D

b = not care

c = not care

Comments:

This command should appear at the beginning of the label format to be in proper ZPL® format.

^MD

Media Darkness

Description:

This ^MD command adjusts the darkness relative to the current darkness setting. The minimum

value is –30 and the maximum value is 30.

Format: ^MDa

Parameters:

a = media darkness level

Accepted Values:-30 to 30,depending on current value.

Initial Value at Power-up:0

If no value is entered, this command is ignored.

Examples:

・If the current value(value on configuration label)is 16,entering the command^MD-9 would

decrease the value to 7.

・If the current value(value on configuration label)is 1,entering the command ^MD15 would increase

the value to 16.

・If the current value(value on configuration label)is 25,entering the command ^MD10 would only

increase the value to 30 since that is the maximum value allowed.

Each ^MD command is treated separately in relation to the current value as printed on the

configuration label.

For example, this is what would happen if two ^MD commands were received.