MINI-MAX Ultrasonic Bolt Tension Monitor

93

10) Press the MENU key multiple times to tab right, and the ESC key

multiple times to tab left, until the AUTO menu is highlighted and

displaying the submenu items.

11) Use the UP and DOWN arrow keys to scroll through the sub menu items

until APPROX LEN is highlighted.

12) Press the ENTER key to display the Digits Edit Box.

13) Press the UP and DOWN arrow keys to scroll the highlighted value.

14) Press the LEFT and RIGHT arrow keys to scroll the digit locations.

15) Repeat steps 10 & 11 until the APPROX LEN value is correctly

displayed.

16) Press the OK key to set the Approximate Length and return to the

menu screen, or ESC to cancel entering the Approximate Length.

17) Use the UP and DOWN arrow keys to scroll through the sub menu

items until AUTO SET is highlighted.

18) Apply a drop of couplant to the bolt or transducer, and attach it to one

end of the bolt. Rotate the transducer clockwise and counter clockwise

applying a small amount of pressure to eliminate any excess couplant

between the transducer and bolt surface. Be sure to always place the