beautypg.com

Dakota Ultrasonics MINI--MAX User Manual

Page 73

background image

MINI-MAX Ultrasonic Bolt Tension Monitor

67

5) Use the CLR key to backspace if necessary.

6) Repeat steps 3 - 5 until the Group Note is completed.

7) Press the OK key to save the Group Note and return to the Group List

Items menu, or ESC to cancel entering the Group Note.

Selecting the Number of Bolts in the Group

Note: A group can contain up to 250 bolts. In this case, the number of

bolts in the group can be thought of as the number of reference points on

the calibration standards. If the 3” & 6” cal bars are being used, then the

group should contain 2 bolts. If the triple sided glass block is being used,

then the group should contain 3 bolts.

1) Use the UP and DOWN arrow keys to scroll through the new Group

List Items until NUM BOLTS is highlighted.

2) Press the ENTER key to display the Digits Edit Box.

3) Press the UP and DOWN arrow keys to scroll the highlighted value.

4) Press the LEFT and RIGHT arrow keys to scroll the digit locations.

5) Repeat steps 3 & 4 until the NUM BOLTS value is correctly displayed.