MINI-MAX Ultrasonic Bolt Tension Monitor

167

Viewing Stored Readings & Waveforms

1) Press the MEAS key once to activate measure menu items. Press the

MEAS key multiple times to move right and the ESC key multiple times

to move left until the LOC cell is highlighted.

2) Press the ENTER key to display the Group View Box.

3) Press the UP, DOWN, LEFT, and RIGHT arrow keys to scroll the stored

readings and corresponding display view. Notice as the cursor is moved

to a different cell, the display will be updated with the display view saved

with the reading.

4) Press the OK and ESC keys to toggle the quantities TIME, ELONG,

LOAD, STRESS, and %STRAIN.