MINI-MAX Ultrasonic Bolt Tension Monitor

49

1) Use the UP and DOWN arrow keys to scroll through the new Group

List Items until INCR. DIR is highlighted.

2) Use the LEFT & RIGHT arrow keys to toggle the Increment direction

NONE, NORTH, EAST, SOUTH, or WEST.

3) When the correct Increment direction is displayed, continue on to the

next section “Saving the Group”.

Saving the Group

Once all the parameters are set, the user has the option of saving or

canceling the new group.

1) Use the UP and DOWN arrow keys to scroll through the new Group

List Items until CREATE NEW GROUP? is highlighted.

2) Press the ENTER key to accept the group parameters, and activate the

confirmation screen.

3) Press the OK key to save the New Group, or the ESC key to cancel the

New Group setup and return to the DATA menu.