E. troubleshooting – Barco CLM HD8 R9050130 User Manual
Page 210
E. Troubleshooting
Error
code
Description
Error
Warning
Caused by
Action
4198
FPGA PMP init
failed
Yes
-
6099
Board ID
unkown
version
Yes
6098
Board ID
invalid string
Yes
7999
DMD temp low
Yes
Yes
Low temperature on DMD
turning on the lamp(s) will heat up
the DMD
7998
DMD temp high
Yes
Yes
High temperature on DMD
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
7997
Ambient temp
low
Yes
Yes
Ambient temperature out of
specifications
take measurements to increase the
temperature
7996
Ambient temp
high
Yes
Yes
Ambient temperature out of
specifications
check ambient conditions
check if air slots are free, clean air
filter.
7995
TEC temp low
7994
TEC temp high
Yes
Yes
7992
LPS1 temp
high
Yes
Yes
High temperature on LPS1
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
7990
LPS2 temp
high
Yes
Yes
High temperature on LPS2
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
7988
LPS3 temp
high
Yes
Yes
High temperature on LPS3
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
7986
LPS4 temp
high
Yes
Yes
High temperature on LPS4
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
7978
Lamp4 temp
high
Yes
Yes
High temperature on lamp 4
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
7924
Fan radiator A
low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7922
Fan radiator B
low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7920
Fan outlet A
low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7918
Fan outlet B
low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7916
Fan power
supply A low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7914
Fan power
supply B low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7912
Fan LPS A low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7910
Fan LPS B low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
206