beautypg.com

E. troubleshooting – Barco CLM HD8 R9050130 User Manual

Page 210

background image

E. Troubleshooting

Error
code

Description

Error

Warning

Caused by

Action

4198

FPGA PMP init
failed

Yes

-

6099

Board ID
unkown
version

Yes

6098

Board ID
invalid string

Yes

7999

DMD temp low

Yes

Yes

Low temperature on DMD

turning on the lamp(s) will heat up
the DMD

7998

DMD temp high

Yes

Yes

High temperature on DMD

check if air slots are free, clean air
filters.

If problem persists, call a qualified
service engineer.

7997

Ambient temp
low

Yes

Yes

Ambient temperature out of
specifications

take measurements to increase the
temperature

7996

Ambient temp
high

Yes

Yes

Ambient temperature out of
specifications

check ambient conditions

check if air slots are free, clean air
filter.

7995

TEC temp low

7994

TEC temp high

Yes

Yes

7992

LPS1 temp
high

Yes

Yes

High temperature on LPS1

check if air slots are free, clean air
filters.

If problem persists, call a qualified
service engineer.

7990

LPS2 temp
high

Yes

Yes

High temperature on LPS2

check if air slots are free, clean air
filters.

If problem persists, call a qualified
service engineer.

7988

LPS3 temp
high

Yes

Yes

High temperature on LPS3

check if air slots are free, clean air
filters.

If problem persists, call a qualified
service engineer.

7986

LPS4 temp
high

Yes

Yes

High temperature on LPS4

check if air slots are free, clean air
filters.

If problem persists, call a qualified
service engineer.

7978

Lamp4 temp
high

Yes

Yes

High temperature on lamp 4

check if air slots are free, clean air
filters.

If problem persists, call a qualified
service engineer.

7924

Fan radiator A
low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7922

Fan radiator B
low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7920

Fan outlet A
low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7918

Fan outlet B
low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7916

Fan power
supply A low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7914

Fan power
supply B low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7912

Fan LPS A low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7910

Fan LPS B low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

206

R59770057 CLM HD8 15/03/2010

This manual is related to the following products: