Installation Procedures: 17" Panels

70

VG-Series Modero Touch Panels

2.

Verify the incoming RJ-45, Ethernet, and any other audio/video cables have been properly threaded
through the wiring knockouts on the left of the conduit box. Leave enough slack in the wiring to
accommodate any re-positioning of the panel.

3.

Connect all data and power wiring connectors to their corresponding locations along the side of the (un-
powered) NXD touch panel.



Verify the terminal end of the power cable is not connected to a power supply before plugging in the

2-pin power connector.



The USB connectors can be from either a USB extension cable, or a wireless USB RF transmitter.

4.

Test the incoming wiring by connecting the panel connections to their terminal locations and applying
power. Verify the panel is receiving power and functioning properly to prevent repetition of the
installation.

5.

Disconnect the terminal end of the power cable from the connected power supply.

6.

Carefully slide the main NXD unit (B in FIG. 57) into the conduit box, so the Mounting Tab lies flush
against the conduit box (C in FIG. 57).

7.

Insert and secure four securing #8 flat-head Mounting Screws into their corresponding holes located
along the sides of the NXD (FIG. 57). These #8 screws are not included within the CB Installation Kit
and must be provided by the installer.

8.

Place the magnetic faceplate (A in FIG. 57) back onto the main NXD unit (B in FIG. 57). Make sure to
align the Microphone, Light, and PIR Motion sensor locations to their respective openings on the front
bezel/faceplate.

9.

Reconnect the terminal RJ-45, Ethernet, and any optional audio/video wiring to their respective locations
(outside the conduit box) on either the NXA-AVB/RGB, Ethernet port, or NetLinx Master.

FIG. 57

Wall Mount panel installation configuration of a CB-TP17 in a pre-wall construction

B - Main NXD unit consists of

C - Optional CB-TP17

Mounting Screws

(not included)

secure the NXD to

Stud

the touch panel and backbox housing

conduit/wallbox

Support block

Mounting Tab

Do not use these

tabs to mount

the conduit /wallbox

These are ONLY used to

secure the main unit to the CB

A - Faceplate

(bezel)

the Conduit Box

Four #8 flat-head

Don’t disconnect the connectors from the touch panel. The unit must be installed with
the attached connectors before being inserted into the conduit box.