beautypg.com

AMX Modero NXD/NXT-1200VG User Manual

Page 160

background image

Firmware Pages and Descriptions

146

VG-Series Modero Touch Panels

Toggling between these three immediately and automatically resets the existing password to the default
password for that setting. With an unsecured panel using the Standard Security setting, the default
password is 1988. With panels using either the Secure or the DoD settings, the default password is
Amx1234! (paying attention to the case of the letters). Entering the existing password will not work and
the default will need to be entered at this point will allow access to the Protected Settings page and allow
resetting of the password to a new one.

For more information on configuring AMX devices for a secure environment, please refer to the guide
Security Profiles: Configuring AMX Devices For Installation Into a Secure Environment, available at
www.amx.com.

Security Profile Features (Cont.)

DOD:

• Must be configured from the program terminal.

• HTTP, Telnet, and FTP are disabled.

• SSH, HTTPS, and program terminal require authentication by an authorized user.

• SSH, HTTPS, and program terminal session timeouts are enabled.

• ICSP communication protocol between devices: encryption and authentication are

enabled.

• Minimum password requirement is 8 characters with at least 1 numeric character, one

uppercase character, one lowercase character, and one special character, with no
duplicate adjacent characters.

• Login failure attempt pauses 4 seconds before another login attempt is allowed.

• After 3 consecutive unsuccessful login attempts, login lockout is enabled for 15

minutes.

• Login and logout audit logging is enabled.

• DoD session banner is enabled.

If the Security button setting is changed in any way, even if it is toggled back to its
original setting, the password is automatically reset to the default for the chosen
setting. You MUST use the new default of 1988 (Standard Security) or Amx1234!
(Secure or DoD) to re-enter the
Protected Settings page.

If accessing the touch panel via telnet, both the default user name AND the default
password will be changed if the Security button setting has been changed. The
defaults are:

username: amx

password: Amx1234!

The correct case must be followed with the username: "AMX" or "Amx" will not work.