Pre-wall installation of the conduit boxes – AMX Modero NXD/NXT-1200VG User Manual
Page 63
Installation Procedures: 12" and 15" Panels
49
VG-Series Modero Touch Panels
8.
Insert and secure the twelve #6-32 securing screws into their pre-drilled holes along the edges of the NXD
unit (FIG. 34). This step secures the NXD unit to the rim of the rear plastic cover.
9.
Align a VESA mount connector (purchased separately) to the four #8-32 screw holes on the back of the
rear plastic cover (FIG. 34).
10.
Insert the four provided #8-32 screws through the VESA mount’s four holes and then into the
pre-drilled holes on the rear plastic cover.
11.
Secure these four #8-32 screws to the rear plastic cover by using a grounded Phillips-head screwdriver.
This step secures the VESA mount to the rear of the panel.
Refer to your particular VESA mount manufacturer’s installation procedures for further surface mounting
procedures.
Pre-wall Installation of the Conduit Boxes
Wall Mount panels (NXDs) are contained within a metallic outer housing (back box). This back box is not
removed when installing the NXD into a conduit box (CB-TP15 or CB-TP12). The back box is only removed
to either gain access for the replacement of the Memory/Compact Flash or upgrade the unit with an MB-TP
Universal VESA Mounting Kit.
The most important thing to remember when mounting this conduit box is that the mounting tabs must be
mounted flush against the outside of the sheetrock.
The CB-TP12 and CB-TP15 conduit wallboxes are optional metallic boxes that are secured onto stud beams
prior to the installation of a solid surface. Installation procedures and configurations can vary. This section
describes the installation procedures for the most common installation scenario.
1.
Fasten the CB-TP15 or CB-TP12 to a stud through the stud fastening holes, located on the inside of the
conduit box (FIG. 38), by using either nails or screws.
When installing a VESA mount to the rear plastic cover, use only the AMX provided
#8-32 screws.
FIG. 37
Installation of grommet into the rear plastic enclosure
Rear plastic cover (rear view)
Rim of the strain relief grommet
should lie flush against enclosure
CLIP FACING UP
VESA mount connection location
(USE ONLY AMX PROVIDED #8-32 screws)
INSTALLER: LEAVE A GAP BETWEEN THE STUD AND CONDUIT BOX TO
ACCOMMODATE THE DRYWALL SHEETROCK.
This gap allows the installation of
the drywall/sheetrock after the conduit box has been installed.