beautypg.com

AMX Modero NXD/NXT-1200VG User Manual

Page 191

background image

Displaying Stream Content

177

VG-Series Modero Touch Panels

Step 5: Establishing the final connection between the two units

1.

Start playing the media at its source (DVD, VCR, camera, etc.)

2.

While in the UI pages (log back in if not already connected), navigate to the Administration page by
clicking on the Admin link from the left Navigation frame.

3.

Locate the Mode section of this page and click the Play button to begin streaming the incoming media
content to the targeted Modero panel. For these procedures, the Program information is optional and not
"picked-up" by the panel.

4.

With the panel now loaded with the new TPD4 project containing the streaming media
page/popup/button, navigate from the initially displayed (main) page to the page containing the
Streaming Video Fill button which we created in the previous step. It should now be displaying the audio
and video from the incoming stream.



If the audio level is not sufficient, you can either go back and create a volume control button or go
to the Modero’s Audio firmware page and adjust the value assigned to the Master Volume for the
panel.



If there is no video being displayed on the page:



Navigate to the firmware pages by pressing the grey Front Setup Access button for

3 seconds to open the Setup page and then press the on-screen Video Adjustment button,
causing an option bar to slide outwards from the Navigation buttons.



Click on the Streaming Adjustment button to launch the Streaming Video Settings page and

confirm that the panel is at least receiving the signal (FIG. 141).



If there is no signal displayed, return to the MAX-CSE UI pages and from the Encoder Profiles

page, confirm that the correct panel IP Address and target port where entered into the Streaming
Source
field within the TPDesign4 project.



If this still doesn’t produce a displayed signal, cycle the Play/Stop buttons and verify that both

the encoding Status says

Streaming

(verifying that the process of encoding is underway) and that

the unit is detecting an incoming signal (shown by the word

SYNC

appearing in the Video Sync

section of the UI).



The most common error can result from a bad cable not being detected and therefore no signal

becomes available for the unit to encode. The encoding process can continue on a MAX-CSE
even without an actual signal being detected.