Installing CAT5 Suppression Ferrites

Before connecting the RJ-45 cables to the Modero Touch Panel, install the necessary number of CAT5
Suppression Ferrites (FIG. 10) to the RJ-45 Audio/Video cable. These ferrites come as part of the Installation
Kits mentioned in the previous Specification table (page 22).
No tools are required for this installation.

1.

The CAT5 Suppression Ferrite is housed within a plastic enclosure (shown in FIG. 10) with a latch
release on one side. Pull to release the latch and open the enclosure.

2.

Grasp the Black RJ-45 Audio/Video cable being connected to the panel. This end of the cable is longer
than the opposing end which connects to the breakout box (6 inches vs 3 inches).
Refer to FIG. 11 for more detailed information.

3.

Insert the panel-end of the Black RJ-45 Audio/Video cable into the groove along the inside of the
enclosure.

4.

Snap the enclosure shut with the cable inside, and you’re done.

5.

Repeat this process again only when installing an additional CAT5 Suppression Ferrite
(model specific).

Wire Table

Wire

Connector 1 Connector 2

Connector 3 Connector 4

1

White/Orange

White/Orange

Red White/Orange

2

Orange/White

Orange/White

Black

Orange/White

3

White/Green

White/Green

-

White/Green

4

Blue/White

Blue/White

-

Blue/White

5

White/Blue

White/Blue

-

White/Blue

6

Green/White

Green/White

-

Green/White

7

White/Brown

White/Brown

-

White/Brown

8

Brown/White

Brown/White

-

Brown/White

FIG. 10

Installing the CAT5 Suppression Ferrites

Release the latch to

open the plastic

enclosure.

Insert the CAT5
cable and close

the enclosure.

Push down on the

enclosure until it

snaps closed.

All 1200V-Series, VG-Series, and Table Top CV10 panels require the installation of
an appropriate number of CAT5 Suppression Ferrites when they use an RJ-45 cable
to feed an A/V signal from the breakout box.

The CAT5 Suppression Ferrites MUST be installed onto the cable connected to the
Modero’s Audio/Video RJ-45 connector (just behind the connector).