AMX Modero NXD/NXT-1200VG User Manual
Page 67
Installation Procedures: 12" and 15" Panels
53
VG-Series Modero Touch Panels
4.
Thread the incoming RJ-45, Ethernet, USB, and any other audio/video wiring (from their terminal
locations) through the cutout opening. Refer to the Wiring Guidelines for the 1200VG and 1500VG
Panels section on page 59 for pinout descriptions. Leave enough slack in the wiring to accommodate any
re-positioning of the panel.
5.
Connect all data and power wiring connectors to their corresponding locations along the side of the (un-
powered) NXD touch panel.
Verify the terminal end of the power cable is not connected to a power supply before plugging in the
2-pin power connector.
The USB connectors can be from a either a USB extension cable, or a wireless USB RF transmitter.
6.
Test the incoming wiring by attaching the panel connections to their terminal locations and applying
power. Verify the panel is receiving power and functioning properly to prevent repetition of the
installation.
7.
Disconnect the terminal end of the power cable from the connected power supply.
8.
Insert the four sets of drywall screws and expansion clips into the four oval notch locations along the top/
bottom edges of the main unit (FIG. 41).
9.
Carefully insert the main unit (with expansion clips) into the cutout until the Mounting Tabs on the NXD
unit lie flush against the wall (FIG. 41).
FIG. 41
NXD-1500VG 15-inch Wall Mount panel dimensions using expansion clips
FRONT BEZEL
*
CUTOUT
*
*
Notches are NOT
SYMMETRICAL
Don’t disconnect the connectors from the touch panel. The unit must be installed with
the attached connectors before being inserted into the drywall.