beautypg.com

AMX Modero NXD/NXT-1200VG User Manual

Page 82

background image

Installation Procedures: 17" Panels

68

VG-Series Modero Touch Panels

4.

Insert one side of the conduit box into the indention on the notched stud and rest the other side of the box
against the opposite beam.

5.

Install and secure a shorter horizontal beam below the conduit box. This beam acts to support the weight
of the box from below and should be secured to both vertical beams (at the sides).

6.

Fasten the CB-TP17 to the Notched stud/beam through the stud fastening holes, located on the inside of
the conduit box (FIG. 56), by using either nails or screws.

7.

Insert a perpendicular block between the Non-Notched stud/beam and the Conduit Box. This block acts
as a bridge to secure the stud/beam to the CB-TP17 along the stud fastening holes located inside of the
box.

8.

Secure the perpendicular block to the Non-Notched stud/beam (FIG. 56) by using either nails or screws.

9.

Fasten the CB-TP17 to the block through the stud fastening holes, located on the inside of the Conduit
Box (FIG. 56), by using either nails or screws.

10.

Remove any necessary wiring knockouts from the (optional) conduit box (CB-TP17) (FIG. 56) where the
necessary cables are threaded through for connection to the touch panel.

11.

Thread the incoming RJ-45, Ethernet, and any other audio/video wiring through the knockouts (use of the
top or bottom knockouts are recommended with this installation). Refer to the Wiring Guidelines for the
1700VG Panels
section on page 78
for pinout descriptions. Leave enough slack in the wiring to
accommodate any re-positioning of the panel.

12.

Install the drywall/sheetrock before inserting the main NXD unit into the CB-TP17.

FIG. 55

CB-TP17 conduit box installation into a notched stud (showing before and after installation)

Mounting

tabs flush on

17.07"

~14" to 16"

the OUTSIDE

of sheetrock

13.554"

(34.43 cm)

(43.36 cm)

Before

After

Use a block to secure the
Conduit Box to the
notched stud

Horizontal

support beam

The determining factor in the depth of the cut into the beam is the thickness of the
drywall. The mounting tabs MUST BE FLUSH against the drywall and therefore, the
depth of the notch depends on that thickness.