AMX Modero NXD/NXT-1200VG User Manual
Page 115
Configuring Communication
101
VG-Series Modero Touch Panels
5.
Verify the yellow LED (from the rear Ethernet port on the Master) is blinking (indicating
communication).
6.
After the panel powers-up, press and hold the grey Front Setup Access button (for 3 seconds) to proceed
to the Setup page.
7.
Select Protected Setup > System Settings (located on the lower-left) to open the System Settings page
(FIG. 83).
Master Connection - Virtual Master communication over Ethernet
Before beginning:
1.
Verify the panel has been configured to communicate either through an Ethernet cable (connected from
either the panel to a valid Ethernet Hub) or wireless to the Wireless Access Point.
2.
Launch NetLinx Studio 2.x (default location is Start > Programs > AMX Control Disc > NetLinx
Studio 2 > NetLinx Studio 2).
3.
Select Settings > Master Communication Settings, from the Main menu to open the Master
Communication Settings dialog (FIG. 84).
FIG. 83
System Settings page
Obtained
from
NetLinx
Master
When configuring your panel to communicate with a Virtual Master (on your PC) via
Ethernet, the Master IP/URL field must be configured to match the IP Address of the
PC and make sure to use the Virtual System value assigned to the Virtual Master
within NetLinx Studio.