Installation of the nxd touch panel, Installing the nxd panel within a conduit box – AMX Modero NXD/NXT-1200VG User Manual
Page 64
Installation Procedures: 12" and 15" Panels
50
VG-Series Modero Touch Panels
2.
Remove any necessary wiring knockouts from the (optional) conduit box (CB-TP12/15)
(C in FIG. 39) where the necessary cables are threaded through for connection to the touch panel.
3.
Thread the incoming RJ-45, Ethernet, and any other audio/video wiring through the knockouts. Refer to
the Wiring Guidelines for the 1200VG and 1500VG Panels section on page 59 for pinout descriptions.
Leave enough slack in the wiring to accommodate any re-positioning of the panel.
4.
Install the drywall/sheetrock before inserting the main NXD unit into the CB-TP12/15.
Installation of the NXD Touch Panel
The NXD panel can be installed either directly into the (optional) CB-TP12/15 or other solid surface
environment using the two different mounting options: drywall clips or solid surface screws. The following
sections describe mounting the touch panel directly into a pre-wall installed conduit box, a solid surface or
drywall, and optional NXA-RK Rack Mount Kit.
Installing the NXD panel within a Conduit Box
The conduit box must be mounted prior to continuing this section. Refer to the procedures in the
Pre-wall Installation of the Conduit Boxes section on page 49 for detailed pre-wall installation instructions.
Verify that all necessary cables have been threaded through the knockouts on the conduit box and the
connections have been tested prior to installation of the NXD panel.
1.
Remove the magnetic faceplate/bezel (A in FIG. 39) from the main NXD unit (B in FIG. 39) by gripping
the faceplate and pulling with gentle outward force.
FIG. 38
Screw locations for conduit box attachment in a pre-wall installation
Drywall/
Stud
Knockouts should be located on the left-side of the
CB-TP Conduit Wallbox
conduit box, alongside the connectors
Stud fastening holes
Use the four #4-40
Mounting Screws to
secure the NXD to the
conduit box at these
sheetrock
Mounting tabs
for NXD panel should
be flush with the outside of the sheetrock
locations