Bbv ?bcb – AMX Modero NXD/NXT-1200VG User Manual
Page 221
Programming
207
VG-Series Modero Touch Panels
All custom events have the following 6 fields:
These fields are populated differently for each query command. The text length (String Encode) field is not
used in any command.
Custom Event Fields
Field
Description
Uint Flag
0 means text is a standard string, 1 means Unicode encoded string
slong value1
button state number
slong value2
actual length of string (this is not encoded size)
slong value3
index of first character (usually 1 or same as optional index
string text
the text from the button
text length (string encode)
button text length
Button Query Commands
?BBV
Get the Battery
Base version.
Returned in Custom event.
Text="None" OR "Base/Docking Station Version number"
Note: V1 Panels only
?BCB
Get the current
border color.
Syntax:
"'?BCB-
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
custom event type 1011:
Flag - zero
Value1 - Button state number
Value2 - Actual length of string (should be 9)
Value3 - Zero
Text - Hex encoded color value (ex: #000000FF)
Text length - Color name length (should be 9)
Example:
SEND COMMAND Panel,"'?BCB-529,1'"
Gets the button 'OFF state' border color. information.
The result sent to the Master would be:
ButtonGet Id = 529 Type = 1011
Flag = 0
VALUE1 = 1
VALUE2 = 9
VALUE3 = 0
TEXT = #222222FF
TEXT LENGTH = 9