Installation Procedures: 12" and 15" Panels

54

VG-Series Modero Touch Panels

10.

Tighten the drywall clip sets (screws and clips) until the Mounting Tabs are securely fastened and flush
against the wall.

11.

Place the magnetic faceplate (A in FIG. 42) back onto the main NXD unit (B in FIG. 42). Make sure to
align the Microphone, Light, and PIR Motion sensor locations to their respective openings on the front
bezel/faceplate.

12.

Connect the terminal RJ-45, Ethernet, USB, and any optional audio/video wiring to their respective
locations on either the NXA-AVB/RGB Breakout Box, Ethernet port, or NetLinx Master.

13.

Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.

FIG. 42

Wall Mount panel (NXD) installation configuration for drywall surfaces

B - Main NXD unit consists of

Install the four drywall

clip sets (included)

into these holes

the touch panel and housing

4 notches are
required if the
unit is installed in
drywall using the
four (4) provided
drywall expansion

A - Faceplate

(bezel)

clips

Mounting Tab

The drywall clip set must be re-ordered from AMX if the drywall clip is bent
accidentally during an installation or removed during a re-installation.