Installation Procedures: 17" Panels
69
VG-Series Modero Touch Panels
Installation of an NXD-1700VG
The NXD-1700VG can be installed either directly into the (optional) CB-TP17 or other solid surface
environment using the two different mounting options: drywall clips or solid surface screws. The following
sections describe mounting the touch panel directly into an installed pre-wall Conduit Box, a solid surface or
drywall, and optional NXA-RK17 Rack Mount Kit.
Installing the NXD-1700VG within a CB-TP17 Conduit Box
The conduit box must be mounted prior to continuing this section. Refer to the procedures in the
Pre-wall Installation of the CB-TP17 Conduit Box section on page 67 for detailed pre-wall installation
instructions. Verify that all necessary cables have been threaded through the knockouts on the conduit box and
the connections have been tested prior to installation of the NXD-1700VG.
1.
Remove the magnetic faceplate/bezel (A in FIG. 57) from the main NXD unit (B in FIG. 57) by gripping
the faceplate and pulling with gentle outward force.
FIG. 56
Screw locations for conduit box attachment in a pre-wall installation
Notched stud
Knockouts should be located on
Inserted block bridges the gap
Stud fastening holes
Mounting tabs for
NXD Wall Mount panel
Use four #8 flat-head
should be flush
with the outside
Stud
of the sheetrock
Mounting Screws to secure
the NXD to the CB
Conduit Box can be
fastened to both
studs)
between the Conduit Box and
the notched beam
Secure Beam to block
Depth depends on the
thickness of the Drywall
Drywall/sheetrock
the left-side of the conduit box,
alongside the connectors