AMX Modero NXD/NXT-1200VG User Manual
Page 120
Configuring Communication
106
VG-Series Modero Touch Panels
7.
The Network Interface Select field is read-only and displays the method of communication to the web.
Verify you have selected the proper interface connection as this field does not auto-detect the
connection type being used (see below).
Wired is used when a direct Ethernet connection is being used for communication to the web. This
is the default setting if either no wireless interface card is detected or if both an Ethernet and
wireless card connection is detected by the panel.
Wireless is used when a wireless card is detected within the internal card slot. This method
provides an indirect communication to the web via a pre-configured Wireless Access Point.
8.
Press the Web Control Name field to open the Web Name keyboard.
9.
From the Web Name keyboard, enter a unique alpha-numeric string to identify this panel. This
information is used by the NetLinx Security Web Server to display on-screen links to the panel. The on-
screen links use the IP Address of the panel and not the name for communication (FIG. 88).
10.
Press Done after you are finished assigning the alpha-numeric string for the Web Control name.
11.
Press the Web Control Password field to open the Web Password keyboard.
12.
From the Web Password keyboard, enter a unique alpha-numeric string to be assigned as the G4
Authentication session password associated with VNC web access of this panel.
13.
Press Done after you are finished assigning the alpha-numeric string for the Web Control password.
14.
Press the Web Control Port field to open the Web Port Number keypad.
15.
Within the keypad, enter a unique numeric value to be assigned to the port the VNC Web Server is
running on. The default value is 5900.
16.
Press Done when you are finished entering the value. The remaining fields within the G4 Web Control
Settings section of this page are read-only and cannot be altered.
17.
Press the Up/Down arrows on either sides of the G4 Web Control Timeout field to increase or decrease
the amount of time the panel can remain idle (no cursor movements) before the session is closed and the
user is disconnected.
18.
Press the Back button to open the Protected Setup page.
19.
Press the on-screen Reboot button to save any changes and restart the panel.
FIG. 88
Sample relationship between G4 Web Control and Mange WebControl Connections window
Verify your NetLinx Master’s IP Address and System Number have been properly
entered into the Master Connection section of the System Settings page.