beautypg.com

Upgrading the nxa-rgb and nxa-avb/rgb firmware – AMX Modero NXD/NXT-1200VG User Manual

Page 133

background image

Upgrading Modero Firmware

119

VG-Series Modero Touch Panels

Upgrading the NXA-RGB and NXA-AVB/RGB Firmware

1.

Identify the Device number of the target panel being used for firmware routing to the accessories.

2.

Complete the instructions for configuring the NetLinx Master for IP communication found in the Step 1:
Prepare the Master for communication via an IP
section on page 113
.

3.

Press the grey Front Setup Access button for 3 seconds to open the Setup page.

4.

Press the Video Adjustment > RGB Adjustment buttons to open the RGB Adjustment page (FIG. 101).
This page displays the firmware for both the internal NXA-RGB card and the communicating external
NXA-AVB/RGB Breakout Box (BOB).

5.

Follow the procedures outlined within the Step 2: Upgrade the NXA-BASE/B firmware via an IP section
on page 117.

If the Base Version field displays 0.00, this means there was an error in the firmware
download process. Re-install the base firmware and re-confirm that the new base
version no longer reads 0.00.

FIG. 101

RGB Adjustment page (showing the default values)

Incoming signal shown in the background

Firmware version of the NXA-RGB card

Firmware version of the NXA-AVB/RGB

If firmware is updated to either the panel or the breakout box, both units must be
power-cycled for the panel to detect and display the new BOB firmware version.