Security Settings
The Security button on the Protected Setup page has three settings: Standard Security, Secure, and
DoD. Each setting has different features for touch panel security:
Protected Setup Page Elements (Cont.)
System Recovery:
Allows you to either reset the touch panel to factory default settings and/or wipe
out all existing touch panel pages:
• The Reset System Settings button allows a user to wipe out all current
configuration parameters on the touch panel (such as IP Addresses, Device
Number assignments, Passwords, and other presets).
- Pressing this button launches a Confirmation dialog that asks you to confirm
your selection.
- This dialog is configured with a delay timer that does not enable the YES
button for 5 seconds. This delay provides an additional amount of time for
the user to confirm their decision.
• The Remove User Pages button allows you remove all current TPD4 touch
panel pages currently on the panel (including the pre-installed AMX Demo
pages).
- Pressing this button launches a Confirmation dialog which asks you to
confirm your selection.
- This dialog is configured with a delay timer that does not enable the YES
button for 5 seconds. This delay provides an additional amount of time for
the user to confirm their decision.
FIG. 118
Button/slider Function Show example
Security Profile Features
Standard Security: • Factory default, shipped in this configuration.
• Administrator and NetLinx user accounts have a default password of "password".
• Telnet, HTTP, HTTPS, and SSH are all enabled and require no authentication.
• Program terminal requires no authentication.
• ICSP communication protocol between devices: encryption and authentication are
disabled.
• FTP is enabled.
• Minimum password requirement is 4 characters.
Secure:
• Must be configured from the program terminal.
• HTTP, Telnet, and FTP are disabled.
• SSH, HTTPS, and program terminal require authentication by an authorized user.
• SSH, HTTPS, and program terminal session timeouts are enabled.
• ICSP communication protocol between devices: encryption and authentication are
enabled.
• Minimum password requirement is 8 characters with at least 1 numeric character.
• Login failure attempt pauses 4 seconds before another login attempt is allowed.
• After 3 consecutive unsuccessful login attempts, login lockout is enabled for 15
minutes.
• Login and logout audit logging is enabled.