User adjustment – RADWAG PS 510.R2.CT Carat Balance User Manual
Page 65
![background image](/manuals/466047/65/background.png)
- 65 -
14.3.3. User adjustment
The external adjustment in balances NPS series should be carried out with
external mass standard / weigh class F
1
Start of external adjustment process,
The first procedure of the process is to enter the mass of the weight that is to
be used for adjustment. The mass must be ≥ 30% Max capacity.
Once the mass of the weight is entered and confirmed, the message is
displayed which asks you to remove the weight from the pan
MASS>
(weighing pan must be empty). After that, press
button, the
balance determines the weight of unloaded pan and message
<CALIBRATION> is shown in the bottom line .
Next, message <PLACE MASS>is displayed in the bottom bar, and in the
main window the value of the mass to be placed e.g. 200.000g (depending
on balance type). Place the weight of the indicated mass and press
button. The balance determines the mass and message <CALIBRATION> is
displayed in the bottom line. After the adjustment process, the balance
returns to submenu P1.2 EXT.CALIB.
If a balance is verified, it is not possible for a user to carry out
external adjustment process.