3. Installation
3−5
Festo GDCP−SFC−LACI−DN−EN en 0812NH
If unused plug connectors are touched, there is a danger that
damage may occur to the SFC−LACI or to other parts of the
system as a result of ESD (electrostatic discharge). Place
protective caps on unused terminal connections in order to
prevent such discharges.
Overview of cables and plugs
Connection
Cable/plug
Type
1
Parameterising interface
Programming cable
KDI−MC−M8−SUB−9−2,5
2
Controller interface
Field bus plug
FBS−SUB−9−BU−2x5POL−B
Field bus adapter
FBA−2−M12−5POL
3
Voltage supply
Power supply cable
KPWR−MC−1−SUB−15HC−...
5
Local digital I/Os
Connecting cable
KM8−M8−... or NEBU−M8−...
6
Motor connection
Motor cable
NEBM−T1G6−T1G6−...
Encoder cable
NEBM−T1G12−T1G12−...
Tab. 3/2:
Overview of cables and plugs (accessories)
For complying with the IP protection class: Tighten the union
nuts/locking screws on the plugs by hand; seal unused M8
connections with type ISK−M8 protective caps (accessories).
Observe the tightening torques specified in the
documentation for the cables and plugs used.
Festo plugs which comply with protection class IP20:
ć screw terminal adapter type FBA−1−SL−5POL
ć field bus plug FBS−SUB−9−WS−CO−K.