Festo Контроллеры двигателя SFC-LAC User Manual
Page 144

5. Commissioning
5−40
Festo GDCP−SFC−LACI−DN−EN en 0812NH
Status byte 2 (SPOS)
Bit
EN
Description
B0
HALT
Halt
= 0: HALT is active
= 1: HALT is not active; axis can be moved
B1
ACK
Acknowledge Start
= 0: Ready for start (reference, jog)
= 1: Start carried out
B2
MC
Motion Complete
= 0: Positioning job active
= 1: Positioning job completed, where applicable with error
Note:
MC is first set after switching on (status Drive blocked")
B3
TEACH
Acknowledge
teaching /
sampling
Depending on the setting in PNU 354:
Ĉ PNU 354 = 0:
Display of the teach status
SPOS.B3 = 0: Ready for teaching
SPOS.B3 = 1: Teaching carried out, actual value
is transferred
Ĉ PNU 354 = 1:
Display of the sampling status
SPOS.B3 = 0: No edge
SPOS.B3 = 1: An edge has occurred
New position value available
On the position sampling: see section 5.6.12
B4
MOV
Axis is
Moving
= 0: Speed of the axis < limit value
= 1: Speed of the axis >= limit value
B5
DEV
Deviation Warning
= 0: No drag error
= 1: Contouring error active
B6
STILL
Stand
still warning
= 0: After MC, axis remains in tolerance window
= 1: After MC axis remains outside tolerance window
B7
REF
Axis is
Referenced
= 0: Drive is not referenced (homing run must be carried out)
= 1: Drive is referenced