B. Parametrizing via field bus
B−53
Festo GDCP−SFC−LACI−DN−EN en 0812NH
Extended Device Errors A
PNU
207
ć
uint16
rw
Description
Reading or deleting the active device fault(s)
Explanations of the error messages can be found in chapter 6.3 Diagnosis"
Writing <0>:
Delete all error messages (in 2FF1h, 2FFAh, 2FFBh and 2FFCh)
Read:
Bit 0 = 1:
Field bus fault (configuration of the parameters)
Bit 1 = 1:
Double MAC address recognized
Bit 2 = 1:
Receive queue overrun
Bit 3 = 1:
Transmit queue overrun
Bit 4 = 1:
CAN bus off, complete bus failed
Bit 5 = 1:
CAN controller queue overrun
Bit 6 = 0:
DeviceNet is reset
Bit 7 = 0:
Faulty bus supply
CI
2FFAh
00h
uint16
rw
DeviceNet
C: 108
Aā: 10
I: 1
uint16
rw
Extended Device Errors B
PNU
208
ć
uint16
rw
Description
Reading or deleting the active device fault(s)
Explanations of the error messages can be found in chapter 6.3 Diagnosis"
Writing <0>:
Delete all error messages (in 2FF1h, 2FFAh, 2FFBh and 2FFCh)
Read:
Bit 0:
ERROR INTERPOLATION CYCLE TIME (with FHPP continuous mode:
missing position specification, missing toggle bit)
Bit 1:
OVERCURRENT POWER STAGE
Bit 2:
LIMIT SWITCH ACTIVATED
Bit 3:
BLOCK DURING JOG MODE
CI
2FFBh
00h
uint16
rw
DeviceNet
C: 108
Aā: 11
I: 1
uint16
rw