Example

The following example configures the https port number to 100.

ip https exec-timeout

The ip https exec-timeout Global Configuration mode command sets the interval for the system wait for user
input in https sessions, before automatic logoff. Use the no form of this command to restore the default
configuration.

Syntax

ip https exec-timeout minutes [seconds]

no ip https exec-timeout

Parameters

minutes — Integer that specifies the number of minutes. (Range: 1 - 65535)

seconds — Additional time intervals in seconds. (Range: 0 - 59)

Default Configuration

The default configuration is the exec-timeout set by the ip http exec-timeout command.

Command Mode

Global Configuration mode

User Guidelines

To specify no timeout, enter the ip https exec-timeout 0 0 command.

Example

The following example configures sets the interval for the system to 1hour.

crypto certificate generate

The crypto certificate generate Global Configuration mode command generates a self-signed HTTPS
certificate.

Syntax

crypto certificate [number] generate [key-generate length] [passphrase string][cn common- name] [ou
organization-unit] [or organization] [loc location] [st state] [cu country] [duration days]

console(config)# ip https port 100

console(config)# ip https exec-timeout 60