2 sending the operating system, 1 sending os with devconfig, Figure 37: devconfig utility – Campbell Scientific CR200/CR200X-series Dataloggers User Manual
Page 72

Section 8. CR200(X) Configuration
Figure 37: DevConfig Utility
8.2 Sending the Operating System
The CR200(X) is shipped with the operating system pre-loaded. However, OS
updates are made available at
www.campbellsci.com
and can be sent to the
CR200(X).
Since sending an OS to the CR200(X) resets memory, data loss will certainly
occur. Depending on several factors, the CR200(X) may also become
incapacitated for a time. Consider the following before updating the OS.
1. Is sending the OS necessary to correct a critical problem? -- If not,
consider waiting until a scheduled maintenance visit to the site.
2. Is the site conveniently accessible such that a site visit can be
undertaken to correct a problem of reset settings without excessive
expense?
If the OS must be sent, and the site is difficult or expensive to access, try the OS
download procedure on an identically programmed, more conveniently located
datalogger.
8.2.1 Sending OS with DevConfig
FIGURE. DevConfig OS Download Window
(p. 61) and
FIGURE. Dialog Box
Confirming OS Download
(p. 61) show DevConfig windows displayed during
the OS download process.
Caution Sending an operating system with DevConfig will erase all
existing data and reset all settings to factory defaults.
60