Table 14. standard sdi-12 command & response set – Campbell Scientific CR200/CR200X-series Dataloggers User Manual

Page 125

background image

Section 11. Programming Resource Library

SDI-12 commands and responses are defined by the SDI-12 Support Group

(www.sdi-12.org) and are summarized in

TABLE. Standard SDI-12 Command

& Response Set

(p. 113). Sensor manufacturers determine which commands to

support. The most common commands are detailed below.

Table 14. Standard SDI-12 Command & Response Set

Name

Command

1

Response

2

Break

Continuous

spacing for at least

12 milliseconds

None

Acknowledge Active

a!

a

Send Identification

aI!

allccccccccmmmmmmvvvxxx...xx

Change Address

aAb!

b (support for this command is required only

if the sensor supports software changeable addresses)

Address Query

?!

a

Start Measurement

3

aM!

atttn

Start Measurement and Request

CRC

3

aMC!

atttn

Send Data

aD0!

.

.

.

aD9!

a or a

a or a

a or a

a or a

a or a

Additional Measurements

3

aM1!

.

.

.

aM9!

atttn

atttn

atttn

atttn

atttn

Additional Measurements and

Request CRC

3

aMC1! ... aMC9!

atttn

Start Verification

3

aV!

atttn

Start Concurrent Measurement

aC!

atttnn

Additional Concurrent

Measurements

aC1!

.

.

.

aC9!

atttnn

atttnn

atttnn

atttnn

atttnn

Additional Concurrent

Measurements and Request CRC

aCC1! ... aCC9!

atttnn

Continuous Measurements

aR0! ... aR9!

a (formatted like the D commands)

Continuous Measurements and

Request CRC

aRC0! ... aRC9!

a (formatted like the D

commands)

1

If the terminator '!' is not present, the command will not be issued. The CRBASIC SDI12Recorder () instruction, however, will

still pick up data resulting from a previously issued "C!" command.

2

Complete response string can be obtained when using the SDIRecorder () instruction by declaring the Destination variable as

String.

3

This command may result in a service request.

113