Section 10. CRBASIC Programming Instructions

TableName.FieldName

Accesses a specific field from a record in a table

Syntax

TableName.FieldName (FieldNameIndex, RecordsBack)

TableName.Output

Determine if data was written to a specific DataTable the last time the

DataTable was called.

Syntax

TableName.Output (1,1)

TableName.Record

Determines the record number of a specific DataTable record.

Syntax

TableName.Record (1,n)

TableName.TableSize

Returns the number of records allocated for a data table

Syntax

TableName.TableSize (1,1)

TableName.TimeStamp

Returns the time into an interval or a timestamp for a record in a specific

DataTable.

Syntax

TableName.TimeStamp (m,n)

10.11 SCADA

Read More! See

Modbus

(p. 139).

Note: These instructions are supported only in a special operating system

version 'M' for CR200 series dataloggers. That operating system must be loaded

on the datalogger and the program compiled with the matching compiler to use

ModBusMaster and ModBusSlave. No special operating system is required for

CR200(X) series dataloggers.
ModBusMaster

Sets up a datalogger as a ModBus master to send or retrieve data from a

ModBus slave.

Syntax

ModBusMaster (ResultCode, ComPort, BaudRate,

ModBusAddr, Function, Variable, Start, Length,

Tries, TimeOut)

ModBusSlave

Sets up a datalogger as a ModBus slave device.

Syntax

ModBusSlave (ComPort, BaudRate, ModBusAddr,

ModBusVariable, BooleanVariable, ByteOrder,

Offset)