Section 10. CRBASIC Programming Instructions

GetValue

Retrieves values from a variable in a data table of a PakBus datalogger.

Syntax

GetVariables (ResultCode, ComPort, NeighborAddr,

PakBusAddr, Security, TimeOut, "TableName",

"FieldName", Variable, Swath)

ReadSendGetInfo

Returns the interval and offset for the SendGetData instruction.

Syntax

ReadSendGetInfo (Dest, Port)

SendData

Sends the most recent record from a data table to a remote PakBus device.

Syntax

SendData (ComPort, NeighborAddr, PakBusAddr,

DataTable)

Note: For the CR200 series, this instruction is supported
only in a special 'S' operating system, version 5.10 and
greater (V06S).

SendGetData

Sends an array of values from a remote CR200(X) to a host datalogger and/or

retrieves an array of data from the host datalogger.

Syntax

SendGetData(ResponseDest, Control, Measurement,

Port, HostAddr, RepeatAddr, Security)

SetValue

Sends values from one or more variables to a remote datalogger's Public table.

Syntax

SetValue (ResponseDest, Source, Swath, RemoteVar,

Port, RemoteAddr, RepeatAddr, Security)

TimeUntilTransmit

The TimeUntilTransmit instruction returns the time remaining, in seconds,

before communication with the host datalogger.

Syntax

TimeUntilTransmit (port)

10.10 Data Table Access and Management

Commands to access and manage data stored in data tables, including Public

and Status tables.
SetStatus

Changes the value for a setting in the datalogger Status table.

Syntax

SetStatus ("FieldName", Value)

106