Campbell Scientific CR200/CR200X-series Dataloggers User Manual

Page 131

background image

Section 11. Programming Resource Library

will respond, however, all other probes will remain active until the timeout

period expires.

Example:

Probe: Water Content

Power Usage:

Quiescent: 0.25 mA

Measurement: 120 mA

Measurement Time: 15 s

Active: 66 mA

Timeout: 15 s

Probes 1, 2, 3, and 4 are connected to SDI-12 / Control Port 1.

The time line in

TABLE. Example Power Usage Profile for a Network of SDI-12

Probes

(p. 119) shows a 35 second power usage profile example.

Table 15. Example Power Usage Profile for a Network of SDI-12 Probes

Sec

Command

All

Probes

Awake

Time

Out

Expires

1 mA

2 mA

3mA

4mA

Total

mA

1

1M!

Yes

120

66

66

66

318

2

120

66

66

66

318

14

120

66

66

66

318

15

Yes

120

66

66

66

318

16

1D0!

Yes

66

66

66

66

264

17

66

66

66

66

264

29

66

66

66

66

264

30

Yes

66

66

66

66

264

31

0.25

0.25

0.25

0.25

1

35

0.25

0.25

0.25

0.25

1

119