FACTORY SETTINGS

INITIAL FACTORY CONFIGURATION (DUAL RATE)

Keys Struck

Display

Description

4,1

41 1

Personality selected as DUAL RATE W/O DISP C

4,2

42 3

Reset Rate A & B outputs

4,3

43 1

Rate B Conversion Factor is Rate Per Second (x1)

4,4

44 1

Rate B Minimum Update time of 0.5 Sec.

4,5

45 4

Rate B Scale Multiplier of 1.0

4,6

46 1

Rate B leading zero blanking and no decimal point

5,1

51 1

Output 1 assigned to Rate A, Output 2 to Rate B

5,2

52 3

Output 1 terminates at Reset, Normal Phase

5,3

0000.10

Timed Output 1 value of 0.1 Sec.

5,4

54 3

Output 2 terminates at Reset, Normal Phase

5,5

0000.10

Timed Output 2 value of 0.1 Sec.

5,6

56 4

No Rate B right hand dummy zeros

6,1

61 4

No Rate A right hand dummy zeros

6,2

62 1

Rate A Conversion Factor is Rate per Second (x1)

6,3

63 1

Rate A Minimum Update Time of 0.5 Sec.

6,4

64 4

Rate A Scale Multiplier of 1

6,5

65 1

Rate A leading zero blanking, no decimal point

6,6

66 1

No functions except Reset enabled

3

01.0000

Scale Factor A (Rate A) set to 1.0000

3

01.0000

Scale Factor B (Rate B) set to 1.0000

1

000500

Preset 1 set to 500

2

001000

Preset 2 set to 1000

DUAL RATE WITH SPEED RATIO FACTORY SETTINGS *

Keys Struck

Display

Description

4,1

41 2

Personality selected as DUAL RATE W/SPEED RATIO

4,2

42 3

Reset Rate A & B outputs

4,3

43 1

Rate B Conversion Factor is Rate Per Second (x1)

4,5

45 4

Rate B Scale Multiplier of 1.0

4,6

46 1

Display C leading zero blanking and no decimal point

5,1

51 1

Output 1 assigned to Rate A, Output 2 to Rate B

5,2

52 3

Output 1 terminates at Reset, Normal Phase

5,3

0000.10

Timed Output 1 value of 0.1 Sec.

5,4

54 3

Output 2 terminates at Reset, Normal Phase

5,5

0000.10

Timed Output 2 value of 0.1 Sec.

6,1

61 1

Display C Multiplier of 1

6,2

62 1

Rate A Conversion Factor is Rate per Second (x1)

6,3

63 1

Rate Minimum Update Time of 0.5 Sec.

6,4

64 4

Rate A Scale Multiplier of 1

6,5

65 1

Rate A & B leading zero blanking, no decimal point

6,6

66 1

No functions except Reset enabled

3

01.0000

Scale Factor A (Rate A) set to 1.0000

3

01.0000

Scale Factor B (Rate B) set to 1.0000

1

000500

Preset 1 set to 500

2

001000

Preset 2 set to 1000

-5-

* If function Code 41 is changed to [41 2], then the factory settings are as shown.