beautypg.com

Red Lion G310 Replacement Backlight User Manual

Ordering information, Figure 1, Figure 2

background image

Bulletin No. G310BK-D
Drawing No. LP0612
Released: 08/13

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

G310C & TX700T BACKLIGHT ASSEMBLIES

G310 BACKLIGHT REPLACEMENT PROCEDURE

1. Remove the power and PLC Communications connectors from the unit.
2. Remove the five screws from the rear cover.
3. Locate the inverter board (refer to Figure 1).
4. Carefully remove heat shrink tubing from the backlight connector on the

inverter board.

5. Carefully remove the backlight connector from its connector housing on the

inverter board. (refer to Figure 1).

6. Depress the backlight release tab and carefully remove the backlight as

indicated in Figure 2.

7. To install the new backlight assembly, reverse the above steps. Ensure that the

florescent tubes of the backlight assembly face towards the display. Use

caution when inserting the new assembly so that it is not twisted or pushed

on an angle. The backlight assembly is fragile and may easily be broken.

8. Apply the enclosed label to the rear cover in the area indicated in Figure 3.

Field replacement of the backlight assembly voids the Hazardous Locations

rating of this unit.

HIGH VOLTAGE

CAUTION

Backlight

Connector

Inverter

Board

See Figure 2

ORDERING INFORMATION

MODEL NO. DESCRIPTION

PART NUMBER

G310

G310C/TX700T Backlight Tube, NEC-29, -46 only

(Note 1)

G3BR10C0

G310C/TX700T Backlight Tube, NEC-64R only

(Note 1)

G3BR10C1

Note 1:

Refer to the part number on the rear of the display in the lower right hand corner.

NEC displays with a part number ending in -29 or -46 must use G3BR10C0.
NEC displays with a part number ending in -64R must use G3BR10C1.
These part numbers are for use with Models G310C and TX700T.

WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT

EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED

AND THE AREA IS KNOWN TO BE NON-HAZARDOUS.

WARNING - EXPLOSION HAZARD - THE AREA MUST BE KNOWN

TO BE NON-HAZARDOUS BEFORE SERVICING/ REPLACING

THE UNIT AND BEFORE INSTALLING OR REMOVING I/O,

INVERTER, BACKLIGHT, WIRING AND BATTERY.

CAUTION

- Backlight is not field replaceable for hazardous

location applications. Unit must be returned to Red Lion

Controls for repair.

CAUTION: RISK OF ELECTRIC SHOCK

The inverter board supplies the high voltage to operate the

backlight. Touching the inverter board may result in injury to

personnel. Disconnect all power before installing or removing

backlight assembly.

Figure 1

Inverter

Board

Release

Tab

Backlight

Display

Figure 2

G310C

G310C

1

AND IS NOT INTENDED FOR PERMANENT CONNECTION.

USB PORT IS FOR SYSTEM SET-UP AND DIAGNOSTICS

DO NOT CONNECT OR DISCONNECT CABLES WHILE POWER

IS APPLIED UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS.

IP ADDRESS

ETHERNET

!

RS485

COMMS PORT

POWER SUPPLY

3

2

1

Tx/R

x

COMMS PORT

RS232

RS232

PGM PORT

LINK

USB

COMMS EXPANSION MODULE

M3619X

LABORATORY EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS

CL I, DIV 2, GP A,B,C,D/CL II, DIV 2, GP F,G/CL III, DIV 2

CLASS II POWER SUPPLY

MODEL G310S
INPUT POWER

24 20% VDC

INPUT POWER

24 20% VDC

MODEL G310C

N/

C

COMMON

24V 20%

!

50W MAX.

33W MAX.

MADE IN U.S.A.

MODEL G310

AMBIENT = 50° C MAXIMUM

ENVIRONMENTAL-IP66 TYPE 4X

OPERATING TEMP. CODE T6

www.redlion.net

RED LION CONTROLS

WHILE POWER IS

APPLIE

D

DO NO

T

REMOVE OR INSER

T

INSE

RT

FA

CE UP

CompactFlash CARD

TM

UL LISTED (HAZARDOUS LOCATIONS) rating.

M3752X

made to this unit have voided the

The field repairs that have been

!

WARNING

Apply label here.

Figure 3