beautypg.com

Appendix “c” - troubleshooting guide – Red Lion GEMINI 52 User Manual

Page 42

background image

APPENDIX “C” - TROUBLESHOOTING GUIDE

-40-

The majority of difficulties arising with the Gemini 5200 are related to incorrect hook-up

and programming set-up. Always check all connections, function codes, Scale Factor, and

presets as a first step in troubleshooting.

Before applying power, double check all wiring. Improper AC voltage or AC connections

may result in permanent damage to the unit.

For further technical assistance, contact technical support at the appropriate company

numbers listed on the back cover of this instruction manual.

PROBLEM

POSSIBLE CAUSE

REMEDIES

NO DISPLAY

1. Power off, improperly connected, or power

1. Check all wiring, verify power.

brown-out.

P ON DISPLAY

1. Data error on power-up.

1a. Press “E” key.

b. Check all function codes.

E ON THE DISPLAY

1. Data error detected by processor.

1a. Press “E” key.

b. Check all function codes.

c. Check signal lines for possible noise sources.

NO RESPONSE TO FRONT PANEL

1. Panel disabled.

1. Consult manual on “Operator Accessible

Functions" modes.

NO RATE INDICATION

1. No input.

1. Check sensors/connections.

2. Input selected incorrectly.

2. Check rear panel DIP switches.

3. Scale factor/multiplier too small.

3. Check scale factor value and scale

multiplier values.

4. Input frequency below 0.03 cps.

4. At frequency under 0.03 cps (1 pulse every

32 sec) the display will read zero.