GENERAL DESCRIPTION

The G308 Operator Interface Terminal combines unique capabilities normally

expected from high-end units with a very affordable price. It is built around a
high performance core with integrated functionality. This core allows the G308
to perform many of the normal features of the Paradigm range of Operator
Interfaces while improving and adding new features.

The G308 is able to communicate with many different types of hardware using

high-speed RS232/422/485 communications ports and Ethernet 10 Base T/100
Base-TX communications. In addition, the G308 features USB for fast downloads
of configuration files and access to trending and data logging. A CompactFlash
socket is provided so that Flash cards can be used to collect your trending and data
logging information as well as to store larger configuration files.

In addition to accessing and controlling of external resources, the G308

allows a user to easily view and enter information. Users can enter data through
the touchscreen or front panel 7-button keypad.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

Do not use the controller to directly command motors, valves, or other

actuators not equipped with safeguards. To do so can be potentially harmful to
persons or equipment in the event of a fault to the controller.

CONTENTS OF PACKAGE

- G308 Operator Interface.
- Panel Gasket.
- This hardware bulletin.
- Template for panel cutout.
- Hardware packet for mounting unit into panel.
- Terminal block for connecting power.

ORDERING INFORMATION

MODEL NO.

DESCRIPTION

PART NUMBER

G308

7.5" TFT Display Operator Interface (indoor),
No USB Host, non-isolated comms

G308C100

8.4" TFT Display Operator Interface (indoor),
USB Host, Isolated Comms

G308A210

8.4" TFT Display Operator Interface (indoor),
Dual Ethernet, USB Host, Isolated Comms

G308A230

G3CF

CompactFlash Card

6

G3CFxxxx

G3RS

RS 232/485 Optional Communication Card

G3RS0000

G3CN

CANopen Optional Communication Card

G3CN0000

G3DN

DeviceNet Optional Communication Card

G3DN0000

G3PBDP

Profibus DP Optional Communication Card

G3PBDP00

GSGSM

GSM/GPRS Modem Option Card

3

G3GSM000

SFCRM

Crimson

2

SFCRM

CBL

RS-232 Programming Cable

CBLPROG0

USB Cable

CBLUSB00

Communications Cables

1

CBLxxxxx

DR

DIN Rail Mountable Adapter Products

4

DRxxxxxx

Replacement Battery

5

BNL20000

G308A Backlight Replacement

CALL

G3FILM

Protective Films

G3FILM08

1

Contact your Red Lion distributor or visit our website for complete selection.

2

Use this part number to purchase Crimson on CD with a printed manual, USB

cable, and RS-232 cable. Otherwise, download for free from www.redlion.net.

3

Antenna (G3QANT00) is NOT included with the card. Must be purchased

separately if needed.

4

Red Lion offers RJ modular jack adapters. Refer to the DR literature for complete

details.

5

Battery type is lithium coin type CR2025

6

Industrial grade two million write cycles. SMART Modular Technologies model

SG9CF (UL Listed Directory Category NWGQ).

MODEL G308C1/A2 - 8" COLOR TOUCHSCREEN

Bulletin No. G308C-E
Drawing No. LP0808
Released 05/12

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

CompactFlash is a registered trademark of CompactFlash Association.

CONFIGURED USING CRIMSON

®

SOFTWARE (VERSION 2.0 OR

LATER)

UP TO 5 RS-232/422/485 COMMUNICATIONS PORTS

(2 RS-232 AND 1 RS-422/485 ON BOARD, 1 RS-232 AND 1
RS-422/485 ON OPTIONAL COMMUNICATIONS CARD)

10 BASE T/100 BASE-TX ETHERNET PORT TO NETWORK UNITS

AND HOST WEB PAGES (2

ND

ETHERNET PORT OPTIONAL-

G308A2 ONLY)

USB PORT TO DOWNLOAD THE UNIT’S CONFIGURATION FROM

A PC OR FOR DATA TRANSFERS TO A PC

UNIT’S CONFIGURATION IS STORED IN NON-VOLATILE

MEMORY (32MBYTE FLASH)

COMPACTFLASH

®

SOCKET TO INCREASE MEMORY CAPACITY

7.5" OR 8.4-INCH TFT 32K VGA 640X480 PIXEL LCD

7-BUTTON KEYPAD FOR ON-SCREEN MENUS

THREE FRONT PANEL LEDS

POWER UNIT FROM 24VDC ±20% SUPPLY

RESISTIVE ANALOG TOUCHSCREEN

CAUTION: Risk Of Danger.

Read complete instructions prior to

installation and operation of the unit.

CAUTION: Risk of electric shock.

WARNING - EXPLOSION HAZARD - SUBSTITUTION OF
COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I,
DIVISION 2

The protective conductor terminal is bonded to conductive
parts of the equipment for safety purposes and must be
connected to an external protective earthing system.

1

C

US LISTED

UL

R

3RSD

PROCESS CONTROL EQUIPMENT

CC

US LISTED

US LISTED

UL

R

43NH

PROCESS CONTROL EQUIPMENT

FOR USE IN HAZARDOUS LOCATIONS:

Class I, Division 2, Groups A, B, C, and D