GENERAL DESCRIPTION

The Gemini 5200 is a multi-function dual rate indicator which can fulfill

almost any rate indication application. The unit can operate as two independent

rate indicators, with scaling, decimal point placement, and update times,

separately programmable for each channel. The Gemini 5200 also has three other

unit personalities. These modes feature a third display channel, C, which can

indicate the ratio, difference or draw between the A and B rate channels.

The programming of the rate channels and the calculated display is very

straightforward. Setting up Channel C only requires programming the desired

amount of resolution (for ratio and draw) and the appropriate decimal point

location. The Gemini 5200 simply takes the two rate values and mathematically

calculates display C accordingly.

The Gemini 5200 20 mA Current Loop Communications option provides the

capability of two-way serial communications between the Gemini 5200 and a

variety of equipment, such as a printer, remote terminal, programmable

controller, or host computer. The baud rate can be set to 300, 600, 1200, or 2400

baud. The format for transmitted and received data is 1 start bit, 7 data bits, 1

parity bit (odd), and a stop bit. When utilizing an external power supply (30 VDC

max.), up to sixteen units can be installed in the loop, each with an individual

address. When utilizing the Gemini’s 20 mA current source, up to seven units can

be installed in a loop. The Rate Values, Presets, and Scale Factor can be

interrogated or changed by sending the proper command codes and numerical

data (if required) to the unit. Various “Print Options” can be selected to

automatically interrogate the Rate Values, Presets, and Scale Factor by

activating the “Print Request” terminal or by sending a “Transmit Per Print

Option” (P) command.

The construction of the Gemini 5200 features a metal die-cast bezel, offering

maximum durability with a high quality die-cast appearance. The sealed front

panel meets NEMA 4/IP65 specifications for washdown and/or dust when

properly installed. Clamp type pressure plate terminals accept stripped #14

AWG wire without lugs.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

manual or on equipment must be observed to ensure personal safety and to

prevent damage to either the instrument or equipment connected to it. If

equipment is used in a manner not specified by the manufacturer, the protection

provided by the equipment may be impaired.

Do not use this unit to directly command motors, valves, or other actuators not

equipped with safeguards. To do so, can be potentially harmful to persons or

equipment in the event of a fault to the unit.

PROGRAMMING THE GEMINI 5200

When your Gemini 5200 arrives from the factory, it has already been

programmed to function as a Dual Rate Indicator without the calculated C

display. It is programmed with the factory settings listed in the “Factory

Settings” section. If it is required to have the unit operate as a speed ratio, speed

difference or draw indicator, the Unit Personality function code can be changed

to do so.

The personality, functions, and modes are accessed by pressing the

appropriate keys as indicated by the embossed numbers above them. A function

is defined by a two-digit code which appears on the left side of the display. The

mode of that function is shown as a one-digit code on the right side of the display.

At times there will be a “-” sign modifier to the left of the mode.

Data for the Presets, Scale Factors and Timed Output Values are entered

differently. Each digit key controls the digit on the display directly above it.

Changing the digits can be done by repeatedly pressing the key beneath the digit

position you wish to change or by holding the key down. As you hold it down, or

repetitively press it, the value of that digit will change cyclically, counting up to

9, then to 0, and then up again. The 6 numbered keys correspond to the six digits,

and the “+/-” key corresponds to polarity.

PROGRAMMING THE PERSONALITY

Entering function and mode is easily accomplished by

pressing the appropriate digit key. For the personality

function, you would enter 41 by pressing the front panel

keys, 4 and 1.

The digits on the left side of the display show the function

code; the digits on the right side show the current

programmed mode.

A new mode selection is made by entering a new number.

On some of the entries, you have the option of a plus “+” or

minus “-” sign. In the cases where a “+” sign is required, no

sign will be displayed. If you do enter a “-” sign (using the

“+/-” key), a minus sign will be displayed in front of the

appropriate digit.

-2-