11. SERIAL COMMUNICATIONS:

Type - Bi-directional 20 mA current loop, 20 mA source provided. (Powers up

to 7 units in a loop with internal current source.)

Baud Rate - Programmable 300 to 2400.

Maximum Address - 16 units. (Actual number in a single loop is limited by

serial hardware specifications.)

Data Format - 10 bit frame, Odd parity (one start bit, 7 data bits, one odd

parity bit, and one stop bit.)

Serial Hardware Specifications -

SO - Output Transistor Rating: V

max

= 30 VDC, V

SAT

= 1 V

max

at 20 mA

SI - Input Diode Rating: V

F

= 1.25 V

TYP

; 1.5 Vmax

Note: The compliance voltage rating of the source must be greater than the

sum of the voltage drops around the loop.

12. OUTPUTS:

Solid-State - Current sinking NPN open collector transistors. I

SNK

= 100 mA

maximum @ V

CE

= 1 V. V

OH

= 30 VDC max. (Internal Zener diode

protection).

Relays - Mounted on a field replaceable PC board. Form C contacts rated at 5

amps @ 120/240 VAC or 28 VDC (resistive load), 1/8 H.P. @ 120 VAC

(inductive load). The operate time is 5 msec. nominal and the release time is 3

msec. nominal.

Relay Life Expectancy - 100,000 cycles at Max. Rating. (As load level

decreases, life expectancy increases.)

Programmable Timed Outputs - The timed outputs can be set from 0.01 to

599.99 seconds, +/-(0.01% + 10 msec.).

13. ENVIRONMENTAL CONDITIONS:

Operating Temperature: 0 to 50°C

Storage Temperature: -40 to 70°C

Operating and Storage Humidity: 85% max. relative humidity

(non-condensing) from 0°C to 50°C.

Altitude: Up to 2000 meters

14. CERTIFICATIONS AND COMPLIANCES:

SAFETY

IEC 1010-1, EN 61010-1: Safety requirements for electrical equipment

for measurement, control, and laboratory use, Part 1.

IP65 Enclosure rating (Face only), IEC529

Type 4 Enclosure rating (Face only), UL50

ELECTROMAGNETIC COMPATIBILITY:

Immunity to EN 50082-2

Electrostatic discharge

EN 61000-4-2 Level 2; 4 Kv contact

1

Level 3; 8 Kv air

Electromagnetic RF fields

EN 61000-4-3 Level 3; 10 V/m

80 MHz - 1 GHz

Fast transients (burst)

EN 61000-4-4 Level 4; 2 Kv I/O

Level 3; 2 Kv power

2

RF conducted interference

EN 61000-4-6 Level 3; 10 V/rms

150 KHz - 80 MHz

Power frequency magnetic fields EN 61000-4-8 Level 4; 30 A/m

Emissions to EN 50081-2

RF interference

EN 55011

Enclosure class A

Power mains class A

Notes:

1. Metal bezel of unit connected with ground lead from rear bezel screw to

metal mounting panel.

2. When the unit is DC powered, a power line filter (RLC #LFIL0000 or

equivalent) was installed, so as not to impair the function of the unit.

Refer to the EMC Compliance Installation section of the manual for

additional information.

15. CONSTRUCTION:

Metal die-cast bezel, plastic case. This unit is rated for NEMA 4/IP65 indoor

use. Installation Category II, Pollution Degree 2

16. WEIGHT: 2.1 lbs (0.9 kg)

-39-