background image

— Degraded - A fan has failed but there are still enough fans in the fan subsystem to keep

the enclosure cool.

— Unknown - The Storage Agents do not recognize the status of the fan subsystem. You

may need to upgrade your software.

— No Fan - This storage system does not have a fan.

Power Supply Status displays the status of the redundant power supply. The following
values are possible:
— OK - All component power supplies that make up the redundant power supply are in

normal working order.

— Degraded - One of the component power supplies that make up the redundant power

supply has failed. The drive system (either a drive subsystem or a power supply for
the main unit) continues to operate. However, if the remaining power supply should
fail, the drive system will lose all power and data loss could occur. To correct this
situation, schedule a time to bring the device down and replace the failed power supply.

— Unknown - The Storage Agents do not recognize the redundant power supply. You

may need to upgrade your software.

— No Redundant Power Supply - This storage system does not support a redundant power

supply.

Thermal Status displays the temperature status of the drive system. The following values
are possible:
— OK - The temperature is within normal operating range.
— Degraded - The temperature is outside of normal operating range. Make sure the cover

is on the storage system.

— Failed - The temperature is outside of normal operating range, and could permanently

damage the system. Ensure that the fans are spinning and check the room temperature.

— Unknown - The Storage Agents do not recognize the thermal status. You may need to

upgrade your software.

— No Temperature Monitoring - This storage system does not support temperature

monitoring.

If the storage system uses Target Based Management (TBM), the following information with
regards to the storage box management will be displayed.

Initiator SAS Address displays the SAS address of the initiator connected to the drive box.

Target SAS Address displays the SAS address of the target (i.e. the drive box itself).

Primary Controller IP Address displays the management IP address for the storage box
primary controller.

Connection Status displays the drive box connection status. The following values are valid:
— Connected - The storage system is connected.
— Not Connected - The storage system is disconnected.
— Not Supported - Reporting this storage system's connection status is not supported.
— Unknown - The Storage Agent is unable to determine the storage system's connection

status. You may need to upgrade your software.

iSCSI Storage Connections

Select an iSCSI Instance entry from the Storage list to display instance and portal information
and a submenu containing separate entries for Node, Session, and Connection information. The
following items may be displayed:

iSCSI Instance Information

Session Information

Connection Information

96