beautypg.com

Management agents for servers for windows® issues, Installation issues, Cannot manage an hp 32‑bit scsi‑2 controller – HP Insight Management Agents User Manual

Page 148: Insight manager cannot manage a system, Insight manager issues, Device not manageable, Cannot manage an hp 32-bit scsi-2 controller

background image

IMPORTANT:

For Windows Server® 2003, Windows® 2000, Windows® NT, NetWare 5.1,

and NetWare 6.0 (SNMP Only), enter the Monitor and Control community strings for the
device. The Insight Management Agents and HP Systems Insight Manager use these
community strings to communicate with the OS SNMP service. Without a Control community
string, certain operations cannot be performed, such as clearing the IML or changing agent
configuration settings.

In Tru64 UNIX, the SNMP daemon must be stopped and restarted before a change in the
SNMP community string is recognized. To stop and start the SNMP daemon, log in as root
and use the following commands, respectively:

# /usr/sbin/snmpd stop

#/usr/sbin/snmpd start

Management Agents for Servers for Windows® issues

As a preliminary troubleshooting step, always examine the Windows Event Log by starting the
Event Viewer application . Management Agents for Servers and other installed software log
significant events into the Windows® Event Log, which might help in diagnosing a problem.
Also, always install all HP drivers from the SmartStart CD before installing the Management
Agents for Servers.

Installation issues

Cannot manage an HP 32-Bit SCSI-2 controller

If an HP 32-bit SCSI-2 controller is added to an existing managed server, activate the SCSI
Information agent . To activate the SCSI Information Agent, perform the following steps:
1.

From the Control Panel, run the Management Agents.

2.

Click the Service tab to display the list of active and inactive agents. A SCSI filter monitor
is required for SCSI management.

3.

Select SCSI Information from the list of Inactive Agents, and then click Add to move it to
the Active Agents list.

4.

Click OK. When prompted to restart the Management Agents, click Yes.

Insight Manager cannot manage a system

If the Microsoft® SNMP service was installed after installing the Management Agents for Servers,
run Install from the Management CD, and select Express to automatically update the Management
Agents.

Cannot delete the CPQMGMT.CPL file when uninstalling or upgrading

When running Windows® 2000, close the Control Panel before deleting the CPQMGMT.CPL file.

Insight Manager issues

Device not manageable

A black indicator appears for the device on the device list.
1.

Verify that the TCP/IP and SNMP services are installed and running under Windows. Check
the Services Control Panel application for status.

2.

Verify that Management Agents for Servers are installed and running under Windows.
Check the Services Control Panel application for Insight Agents.

3.

Verify that the device community string matches the community string specified in Insight
Manager. The device community string is located in the Networks Control Panel application
under Configure SNMP Service. The Insight Manager community string is set in the Device
Setup window from the management console (select Device Setupfrom the Task List

148