beautypg.com

Identify drives – HP Insight Management Agents User Manual

Page 68

background image

— Read Failure - Write cache operations have been permanently disabled. The Array

Accelerator board stores duplicate copies of all data. While reading the data from the
board, memory parity errors have occurred so both copies were corrupted and cannot
be retrieved. Data has been lost. Have the board serviced.

— Write Failure - Write cache operations have been permanently disabled. This error

occurs when an unsuccessful attempt was made to write data to the Array Accelerator
board. Data could not be written to write cache memory in duplicate due to the detection
of parity errors. This error does not indicate data loss. Have the Array Accelerator board
serviced.

— Config Command - Write cache operations have been permanently disabled. The

configuration of the logical drives has changed. Reconfigure the Array Accelerator
board.

— Expand in Progress Cache operations are temporarily disabled due to an expand of a

logical drive. When the expand operation completes, the accelerator will be enabled.

— Snapshot in Progress - Cache operations are temporarily disabled due to a snapshot

operation that is queued up or in progress. When the snapshot operation completes,
the accelerator will be enabled.

— Redundant Low Battery - Cache operations are temporarily disabled. The redundant

controller has insufficient cache battery power.

— Redundant Size Mismatch - Cache operations are temporarily disabled. The cache sizes

on the redundant controllers do not match.

— Redundant Cache Failure - Cache operations are temporarily disabled. The cache on

the redundant controller has failed.

— Excessive ECC Errors - Cache operations have been permanently disabled. The number

of cache lines experiencing excessive ECC errors has reached a preset limit.

— POST ECC Errors - Indicates that write cache operations have been permanently disabled.

The cache has been disabled due to a large number of ECC errors detected while testing
the cache during the Power On Self Test (POST).

— Unknown - The Storage Agents do not recognize the error code. You may need to update

your software.

Identify Drives

Select the length of time to identify the physical drives that are connected to this controller from
the drop-down list box and then select the Start button. The page will automatically refresh and
display an image of an identified drive and a Stop button. Select the Stop button to end
identification before the time expires.

After the drive identification completes, the page will have to be manually refreshed to display
the Start button. There may be a delay, depending on the length of the HP Management Agents
data collection interval, after the drive identification completes and before the Start button can
be displayed.

Only drives in hot plug trays are supported since the LEDs are part of the tray. If an individual
logical drive or physical drive on this controller is selected while the drives connected to this
controller are currently identified then the other drives will stop identification and only the
selected drive will be identified.

When there are redundant controllers only the active controller can be used to identify the drives
connected to the controller.

68