HP Insight Management Agents User Manual
Page 36
— Unsupported Drives—One or more attached drives has been determined to be incapable
of properly supporting redundant controller operation.
— Expand in Progress—An expand operation is in progress. Redundant operation not
supported until the expand operation is complete.
— Unknown—Indicates that the Storage Agents are unable to determine the redundancy
error for the controller. You may need to upgrade the Storage Agents.
•
Firmware Version—Lists the firmware version of the array controller. This value can be
used to help identify a particular revision of the controller.
•
Product Revision—Displays the revision of the array controller board. This value can be
used to help identify a particular revision of the controller.
•
Serial Number—Displays the serial number for the array controller. Use this number for
identification purposes.
•
Processor Usage—Displays the total percentage of the processor usage, expressed as a
number from 0 to 100 inclusive.
•
Command Count—Displays the total number of read and write commands processed in
this sample. This value is expressed as read and write commands per second.
•
Command Latency—Displays the average command latency for this sample in 1/100,000 of
a second units.
•
ADG Enabler Status—Displays the array controller RAID ADG Enabler Module status. The
module enables advanced controller features such as Advanced Data Guarding. The following
values are valid:
— Not Supported—Indicates that the RAID ADG Enabler Module is not supported by
this type of controller.
— Not Present—Indicates that the RAID ADG Enabler Module is not present or is not
accessible.
— Fully Functional—Indicates that the RAID ADG Enabler Module is functional and
accessible.
— Bad Signature—Indicates that the RAID ADG Enabler Module has an incorrect signature.
— Bad Checksum—Indicates that the RAID ADG Enabler Module checksum failed.
— Present - Upgrade Firmware—Indicates that the RAID ADG Enabler Module is installed,
but a firmware upgrade is required to make it fully functional.
— Unknown—Indicates that the Storage Agents do not recognize the RAID ADG Enabler
Module. You may need to upgrade the Storage Agents.
•
Daughter Board Type—Displays the type of daughter board installed on the array controller.
The following values are valid:
— Not Supported—Indicates that the array controller does not support daughter boards
or it does not support daughter board identification.
— Not Present—Indicates that a daughter board is not installed on the array controller.
— SCSI—Indicates that a SCSI daughter board is installed on the array controller.
— Fibre—Indicates that a Fibre daughter board is installed on the array controller.
— Array—Indicates that an Array Expansion Module is installed on the array controller.
— Unknown—Indicates that the daughter board type is not recognized. You may need to
upgrade the Storage Agents.
•
Rebuild Priority—Displays the logical drive rebuild priority of the controller. The following
values are valid:
— Low—Indicates the rebuild priority is low.
— Medium—Indicates the rebuild priority is medium.
— High—Indicates the rebuild priority is high.
— Unknown—Indicates that the rebuild priority is not recognized. You may need to
upgrade the Storage Agents.
36
Agent information