Environment monitoring unit, External expansion cabinet – HP Insight Management Agents User Manual
Page 141
The following is a list of devices in CR3500 Shared Storage system:
•
Clustered RAID Controller
•
RAID Array
•
Physical Drive
•
Spare Drive
•
Environment Monitoring Unit
Environment Monitoring Unit
•
This section displays the Environment Monitoring Unit information.
•
Primary enclosure temperature status—Displays the current primary enclosure temperature
status. The following conditions are valid:
— OK—The primary enclosure temperature is within normal parameters.
— Critical—The controller temperature sensor has detected a critical temperature condition
in the primary enclosure.
— Non-critical—The controller temperature sensor has detected an abnormal temperature
condition in the primary enclosure.
— Unknown—The enclosure temperature information is unavailable.
•
Primary enclosure temperature—Displays the current primary enclosure temperature in
degrees Celsius.
•
Primary enclosure fan status—Displays the current primary enclosure fan status. The
following conditions are valid:
— OK—The fan status is normal.
— Critical—The fan has failed.
— Unknown—The enclosure fan status information is unavailable.
•
Primary power supply status—Displays the current primary power supply status. The
following conditions are valid:
— OK—The power supply status is normal.
— Critical—The power supply is installed and marked as failed.
— Not Installed—One of the redundant power supplies has been removed.
— Unknown—The power supply status information is unavailable.
External Expansion Cabinet
This section displays the External Expansion Cabinet information. The following conditions are
valid:
•
Power Supply Status—Displays the current status. The following conditions are valid:
— OK—All power supply parameters are normal.
— Non-Critical—The redundant power supply is reporting a fault that is not critical to
operation.
— Not Installed—One of the redundant power supplies has been removed.
— Unknown—The power supply information is unavailable.
•
Fan Status displays the current fan status. The following conditions are valid:
— OK—All fans are operating normally.
— Critical—A fan has failed.
— Non-Critical—A fan is in a degraded condition.
Environment Monitoring Unit
141