beautypg.com

Environment monitoring unit, External expansion cabinet – HP Insight Management Agents User Manual

Page 141

background image

The following is a list of devices in CR3500 Shared Storage system:

Clustered RAID Controller

RAID Array

Physical Drive

Spare Drive

Environment Monitoring Unit

Environment Monitoring Unit

This section displays the Environment Monitoring Unit information.

Primary enclosure temperature status—Displays the current primary enclosure temperature
status. The following conditions are valid:
— OK—The primary enclosure temperature is within normal parameters.
— Critical—The controller temperature sensor has detected a critical temperature condition

in the primary enclosure.

— Non-critical—The controller temperature sensor has detected an abnormal temperature

condition in the primary enclosure.

— Unknown—The enclosure temperature information is unavailable.

Primary enclosure temperature—Displays the current primary enclosure temperature in
degrees Celsius.

Primary enclosure fan status—Displays the current primary enclosure fan status. The
following conditions are valid:
— OK—The fan status is normal.
— Critical—The fan has failed.
— Unknown—The enclosure fan status information is unavailable.

Primary power supply status—Displays the current primary power supply status. The
following conditions are valid:
— OK—The power supply status is normal.
— Critical—The power supply is installed and marked as failed.
— Not Installed—One of the redundant power supplies has been removed.
— Unknown—The power supply status information is unavailable.

External Expansion Cabinet

This section displays the External Expansion Cabinet information. The following conditions are
valid:

Power Supply Status—Displays the current status. The following conditions are valid:
— OK—All power supply parameters are normal.
— Non-Critical—The redundant power supply is reporting a fault that is not critical to

operation.

— Not Installed—One of the redundant power supplies has been removed.
— Unknown—The power supply information is unavailable.

Fan Status displays the current fan status. The following conditions are valid:
— OK—All fans are operating normally.
— Critical—A fan has failed.
— Non-Critical—A fan is in a degraded condition.

Environment Monitoring Unit