External array storage systems, Storage system information, Storage system chassis information – HP Insight Management Agents User Manual
Page 59
•
No Redundant Power Supply—This ProLiant server does not support a redundant power
supply.
•
Paths—Displays the status and role of each data path to the storage system (for multipath
capable hardware only). The following values are possible:
— Path—Indicates the path to the storage system. Each path is identified by a descriptor.
For example, "Port 2E Box 1" indicates a path from the host adapter external port number
2 ("Port 2E") to the first box.
— Status—Indicates the status of the data path. Possible values are:
◦
OK—The path is operational.
◦
Link down—The path is not operational.
◦
Unknown—The path status cannot be determined.
— Role—Indicates the role of this path in the configuration. Possible values are:
◦
Active—This path is the preferred data path to the storage system.
◦
Alternate—This path is the alternate data path to the storage system.
◦
Unknown—The role of this path cannot be determined.
External Array Storage Systems
This section displays general and status information about external array storage systems. Select
an external array storage system entry from the Mass Storage list to display a submenu containing
separate entries for storage systems, array controllers, physical drives, and logical drives. The
following items display:
•
Storage System Information
•
Array Controller Information
•
Accelerator Information
•
Physical Drive Information
•
Logical Drive Information
•
Snapshot Resource Volumes
•
Fibre Channel Switch Information
•
RAID Array Storage Systems
•
External Storage Connections
Storage System Information
Select the Storage System Information entry from the Mass Storage submenu to display the
following information about an external array storage system:
Storage System Chassis Information
•
Model displays the type of storage system chassis.
•
Name displays the user-defined name (or serial number, if preferred) of this storage system
chassis.
•
Connection Type displays the type of connection between the server and the box. The
following values are possible:
— Fibre Attached - This chassis is attached to the server through Fibre Channel.
— SCSI Attached - This chassis is attached to the server with a SCSI cable.
— SAS Attached - This chassis is attached to the server with a SAS cable.
— Unknown - The Storage Agents are unable to determine the type of connection.
•
Serial Number displays the storage system chassis serial number, which is normally displayed
on the front panel. Use this information for identification purposes.
Storage Agent