beautypg.com

HP Insight Management Agents User Manual

Page 58

background image

Connection Type—Displays the type of connection between the server and the box. The
following values are possible:
— Fibre Attached—This chassis is attached to the server through Fibre Channel.
— SCSI Attached—This chassis is attached to the server with a SCSI cable.
— SAS Attached—This chassis is attached to the server with a SAS cable.
— Unknown—The Storage Agents are unable to determine the type of connection.

Drive Bays—Displays the number of drive bays provided by this storage system. If duplexing
hardware is used with the storage system, the drive bay number is less than the number of
physical drive bays in the enclosure.

Model—Displays the model of the storage system. Use this information for identification
purposes.

Board Revision—Displays the board revision level of this storage system backplane.

Thermal Status—Displays the temperature status of the drive system. The following values
are possible:
— OK—The temperature is within normal operating range.
— Degraded—The temperature is outside of normal operating range. Check to make sure

the cover is on the storage system.

— Failed—The temperature is outside of normal operating range, and could permanently

damage the system. Ensure that the fans are spinning, and check the room temperature.

— Unknown—The Storage Agents do not recognize the thermal status. You may need to

upgrade your software.

No Temperature Monitoring—This storage system does not support temperature monitoring.

Side Panel—Displays the status of the side panel of the drive enclosure, or box. The following
values are possible:
— In Place—The side panel is closed.
— Removed—The side panel is not in place or not completely closed.
— Unknown—The Storage Agents do not recognize the side panel status. You may need

to upgrade your software.

No Panel Detection—This storage system does not support side panel detection.

Duplex Option—Displays the duplex option installed in this storage system. The following
values are possible:
— Duplex Top—This storage system is the top part of a duplexed unit.
— Duplex Bottom—This storage system is the bottom part of a duplexed unit.
— None—A duplex option is not installed.

Power Supply Status—Displays the status of the redundant power supply. The following
values are possible:
— OK—All component power supplies that make up the redundant power supply are in

normal working order.

— Degraded—One of the component power supplies that make up the redundant power

supply has failed. The drive system (either a drive subsystem or a power supply for
the main unit) continues to operate; however, if the remaining power supply should
fail, the drive system loses power and data loss could occur. To correct this situation,
schedule a time to bring the device down and replace the failed power supply.

— Unknown—The Storage Agents do not recognize the redundant power supply. You

may need to upgrade your software.

58

Agent information