World Wide Node Name displays the unique Fibre Channel node name for the controller.
Use this value to further identify a particular controller.

Rebuild Priority displays the logical drive rebuild priority of the controller. The following
values are valid:
— Low - indicates the rebuild priority is low.
— Medium - indicates the rebuild priority is medium.
— High - indicates the rebuild priority is high.
— Unknown - indicates that the rebuild priority is not recognized. You may need to

upgrade the Storage Agents.

Expand Priority displays the logical drive expand priority of the controller. The following
values are valid:
— Low - indicates the expand priority is low.
— Medium - indicates the expand priority is medium.
— High - indicates the expand priority is high.
— Unknown - indicates that the expand priority is not recognized. You may need to

upgrade the Storage Agents.

Controller Status displays the status of the controller hardware. The following values are
valid:
— OK - The controller is operating normally.
— Failed - The controller has failed and is no longer operating.
— Offline - The controller is offline.
— Redundant Path Offline - There are multiple connection paths to this controller. At least

one connection path is available and at least one connection path is not available.

— Unknown - Indicates that the Storage Agents are unable to determine the status of the

controller. You may need to upgrade the Storage Agents.

Current Role displays the array controller's current role for duplexed array controllers. The
following values are valid:
— Not Duplexed - This array controller is not duplexed.
— Active - This duplexed array controller is the active controller.
— Backup - This duplexed array controller is the backup controller.
— Unknown - Indicates that the Storage Agents are unable to determine the role of the

controller. You may need to upgrade the Storage Agents.

Redundancy Type displays the type of redundant configuration. The following values are
valid:
— Not Redundant - This array controller is not in a redundant configuration.
— Firmware Active/Standby - The array controller is using an active/standby algorithm

implemented in the controller firmware and the operating system driver.

— Firmware Primary/Secondary - The array controller is using a primary/secondary

algorithm implemented in the controller firmware and the operating system driver.

— Unknown - Indicates that the Storage Agents are unable to determine the type of

redundancy for the controller. You may need to upgrade the Storage Agents.

Redundancy Error displays the redundancy error for the controller. The following values
are valid:
— No Failure - No failures have been detected.
— No Redundant Controller - No redundant controller is installed.
— Different Hardware - The other controller indicates a different hardware model.
— No Link - A link to the other controller could not be established.
— Different Firmware - The other controller indicates a different firmware version.
— Different Cache - The other controller indicates a different cache size.

Storage Agent