Installing the pass-thru mechanism in the rack – HP Compaq StorageWorks TL881 DLT Mini-Library User Manual
Page 92
Installation 3-23
2
1
2
1
2
1
2
1
2
1
2
1
9
10
3
1
4
5
6
7
8
2
SHR-1244
Figure 3-13. Metric Rackmount Installation Layout
1 Attached mounting bracket
6 Outer right side
2 968313-101
7 968313-101
3 Rear rail of StorageWorks
metric rack (attach this end
first)
8 Front rail of StorageWorks
metric rack (where MiniLibrary
Base Module face will reside
4 Nut plate;
9 968312-101
5 Lock tab
- Threaded post for thumbscrew
IMPORTANT: See Appendix E,
Information on Pass-Thru Section Covers.
Installing the Pass-Thru Mechanism in the Rack
1.
If you have not previously done so, install the angle brackets on the rack
slide extensions of the top and bottom modules, using one 10-32 screw
and an L-shaped nut plate for each angle bracket. The L-shaped nut
plates should hang from the top of the slide extensions on the outside.
Place the angle brackets so the front edge of the vertical part is 15/16”
behind the rear edge of the slide body, as shown in the inset in Figure 3-
14.
2.
Referring to Figure 3-14, position the Pass-Thru mechanism against the
back of the installed modules so that the support braces rest on the
previously installed angle brackets. Install an M4 x 20 mm screw and
washer through the rear hole in each angle bracket into the support
braces. Do not tighten.