2-12 Compaq TL881 Minilibrary System Users Guide

Fault Screen

When a fault is detected within the Expansion Unit or the Pass-Thru
Mechanism, a screen similar to Figure 2–10 appears.

When a fault is detected in one of the MiniLibrary Base Modules, the Alert
LED on the Expansion Unit control panel comes on. The Fault Screen appears
on the malfunctioning MiniLibrary Base Module. At the same time, either the
Drive Fault or the Loader Fault LED is illuminated on that module.

SHR-1345

Figure 2-11. Fault Screen

The first line in Figure 2–10 shows a numerical fault symptom code (FSC).
The second line shows a brief description of the error, in place of the words,
‘Error Description'. The third and fourth lines will contain a one- or two-line
message describing the initial error recovery procedure (ERP) in place of the
words shown in the Fault Screen.

A list of the fault symptom codes (FSC) and error recovery procedures (ERP)
appears in Chapter 6, Diagnostics and Troubleshooting.

MiniLibrary Base Module Default Screen

The MiniLibrary Base Modules display a different Default Screen, as shown in
Figure 2–11:

SHR-1447

Figure 2-12. MiniLibrary Base Module Default Screen

The example shows a MiniLibrary Base Module in the module 1 position. The
first and second lines of the Default Screen show the status of the two drives
within the MiniLibrary Base Module. On line 4, a rectangle appears in each
position that contains a cartridge. An underline would appear at each empty