Installation 3-37
Figure 3-30. Set Mail Slot Submenu
3.
With the
next to line 1, press the
Enter
button. The
moves to line
2 and
appears at the end of line 4. Now you can use the
and
buttons to scroll line 2 to display the possible settings. These options
enable you to specify which module should have the mail slot enabled.
Scroll downward to the desired module, then press the
Enter
button to
save the new selection.
NOTE: The Expansion Unit is not on the list. Module 1 refers to the MiniLibrary Base
Module just below it.
4.
Scroll line 2 to display Module 1, then press the
Enter
button to select it.
The screen changes as shown in Figure 3-31:
SHR-1341
Figure 3-31. Set Mail Slot Submenu Enabled
5.
The
returns to line 1. Press the
button. The
moves to line 3.
6.
Press the
Enter
button The
moves to line 4. Now you can use the
and
buttons to scroll line 4 to specify how many slots will be
designated as mail slots. Scroll to the desired number, then press the
Enter
button to save the new selection
7.
Press the
Escape
button repeatedly to return to the Default Screen.
Reserved Slots
Some host software imposes size limits on tape library magazines for licensing
purposes, and will not operate with a library that exceeds the licensed size.
This configuration option enables you to withdraw some of the slots in the
Expansion Unit from use as storage slots in order to meet licensing
requirements.
1.
As shown in Figures 3-25 through 3-27, navigate from the Default
Screen through the Main Menu to the Configure Submenu.
2.
Scroll down on the Configure Submenu until you see ‘Set Reserved
Slots’, and select that option. The screen shown in Figure 3-32 appears: