beautypg.com

Minilibrary base module – HP Compaq StorageWorks TL881 DLT Mini-Library User Manual

Page 31

background image

Operation 2-5

Table 2-1
Control Panel Button Functions

continued

Screen

Escape

Enter

s Note 1

t Note 1

At Fault
Screen

N/A

Clears Soft
Errors

N/A

N/A

Notes:

1 There is an auto-repeat feature for the

s and t buttons. When the user presses either

button for more than one-half second, the control panel behaves as if the user were
pressing and releasing the button about four times per second. This effect stops when the
user releases the button.

2 This button is sampled during power-up while all control panel LEDs are on. If it is
depressed during that time, the system updates its geometry; that is, it checks for the
presence and location of all modules and remaps all media. Use this method when
removing or installing a module permanently.

3 These buttons are sampled during power-up. If

both are depressed during that time, the

system clears low-power memory. Use this procedure only when low-power data is
corrupted. Clearing low-power memory erases all log information, such as configuration
history, error history, and statistics. In addition, the system time, date and password
information is erased and must be re-entered.

MiniLibrary Base Module

Figure 2–3 shows the front panel of the MiniLibrary Base Module. The panel
includes a power switch and the Control Panel, which has pushbuttons, LED
indicators, and a display.

SHR-1195

Use

Cleaner

Drive

Fault

Load

er

Fault

Figure 2-3. MiniLibrary Base Module Front Panel